Product Information
Key Specifications/ Special Features
| Model | I/P condition | voltage | current | Max power |
| KCH0503100 | 100-240VAC 0.6A max 50/60hz | 3.6-8.9V DC | 0.3-3.1A | 15.5W |
| KCH0902000 | 100-240VAC 0.6A max 50/60hz | 9-11.9V DC | 0.1-2A | 18W |
| KCH1201500 | 100-240VAC 0.6A max 50/60hz | 12-17.9V DC | 0.1-1.5A | 18W |
| KCH1801000 | 100-240VAC 0.6A max 50/60hz | 18-30v dc | 0.1-1A | 18W |
Usb power adapter 18W charger
product highlights:
1.lightweight ,streamline,omniseal,portable
2.IC design,performance stable,ultrasonic combination
3.bulit-in OVP,OCP and SCP triple protection ;high security performance
4.input secification
input:AC90-264V(Fit for global voltage) Frequency:50/60HZ;
startup time ≤ 3s
inrush current ≤ 30A/240VAC
5.OUTPUT sepecification
a, voltage :DC3.6V-30V current:0.1A-3.5A POWER:18w MAX
b,Automation recover normal afer OVP,OCP and SCP malfuntion ternination;
c, high accuracy output:voltage fluctuation ratio:±5% load fluction ratio:±1% lowe noise and environmental protection
6.Reliability test :
a,aging test :over 4hs aging under 30℃±10℃ and 100% rated load.
b,Drop test:1m highness throw to 30mm thick wood board ,each side 1tim
c, high voltage test:AC3000V/5MA
7.Safety standards:IEC/EN60065 IRC/EN60950
8.Plug gauge;CCC/US/EU/UK/PSE/EK
9.MTBF:50000H(25℃ regular input)
Production system:
1.Incoming sampling, plug-in full inspection
2.Welding inspection:Automatic welding,Full inspection
3.According to customer’s market demand :220v/110v voltage test. Full inspection
4.Assembly section : full inspection
5.Aging test: 4 hours Electronics load,fully automatic full inspection
6.package , HI-POT TEST,the appearance and the temperature Full inspection
7.Parking the finished product
Protection Function
1.Output short circuit protection:The Power will not be damaged when the output is short circuited and recover normal work after the short is removed.
2. Output Over Load Protection:The Power will not be damaged when the output over load and recover normal work after the faults is removed.
Reliability Requirements
1.Burn-in:all products burn-in 4 hours at 40℃± 5℃under full load condition
2.HI-POT TEST; INPUT TO OUTPUT:3000VAC 60 SEC (production 3300VAC 3 SEC)Leakage
| Model | I/P condition | voltage | current | Max power |
| KCH0503100 | 100-240VAC 0.6A max 50/60hz | 3.6-8.9V DC | 0.3-3.1A | 15.5W |
| KCH0902000 | 100-240VAC 0.6A max 50/60hz | 9-11.9V DC | 0.1-2A | 18W |
| KCH1201500 | 100-240VAC 0.6A max 50/60hz | 12-17.9V DC | 0.1-1.5A | 18W |
| KCH1801000 | 100-240VAC 0.6A max 50/60hz | 18-30v dc | 0.1-1A | 18W |
Usb power adapter 18W charger
product highlights:
1.lightweight ,streamline,omniseal,portable
2.IC design,performance stable,ultrasonic combination
3.bulit-in OVP,OCP and SCP triple protection ;high security performance
4.input secification
input:AC90-264V(Fit for global voltage) Frequency:50/60HZ;
startup time ≤ 3s
inrush current ≤ 30A/240VAC
5.OUTPUT sepecification
a, voltage :DC3.6V-30V current:0.1A-3.5A POWER:18w MAX
b,Automation recover normal afer OVP,OCP and SCP malfuntion ternination;
c, high accuracy output:voltage fluctuation ratio:±5% load fluction ratio:±1% lowe noise and environmental protection
6.Reliability test :
a,aging test :over 4hs aging under 30℃±10℃ and 100% rated load.
b,Drop test:1m highness throw to 30mm thick wood board ,each side 1tim
c, high voltage test:AC3000V/5MA
7.Safety standards:IEC/EN60065 IRC/EN60950
8.Plug gauge;CCC/US/EU/UK/PSE/EK
9.MTBF:50000H(25℃ regular input)
Production system:
1.Incoming sampling, plug-in full inspection
2.Welding inspection:Automatic welding,Full inspection
3.According to customer’s market demand :220v/110v voltage test. Full inspection
4.Assembly section : full inspection
5.Aging test: 4 hours Electronics load,fully automatic full inspection
6.package , HI-POT TEST,the appearance and the temperature Full inspection
7.Parking the finished product
Protection Function
1.Output short circuit protection:The Power will not be damaged when the output is short circuited and recover normal work after the short is removed.
2. Output Over Load Protection:The Power will not be damaged when the output over load and recover normal work after the faults is removed.
Reliability Requirements
1.Burn-in:all products burn-in 4 hours at 40℃± 5℃under full load condition
2.HI-POT TEST; INPUT TO OUTPUT:3000VAC 60 SEC (production 3300VAC 3 SEC)Leakage

,Manufacturer ,Online Seller ,Trading Company ,Wholesaler 